Bison WP20 Site Pump Bundle Complete 2" Construction, Utilities & Flood Pump Kit.
Petrol Pump, Assembled Hoses, Camlock Connections and Engine Oil in One Bundle
The Bison WP20 Site Pump Bundle brings together the pump and hose equipment needed for construction site dewatering, outdoor flood response, irrigation and clean-water transfer.
Built around the 196cc, four-stroke Bison WP20 petrol pump, this package includes a 6-metre suction hose, 25-metre layflat delivery hose, suction strainer, Camlock connections and 1 litre of engine oil. The hoses arrive assembled with their fittings, reducing the work involved in preparing a pumping system.
With no mains electricity or generator required, it is a practical option for contractors, farmers and property owners working away from an electrical supply.
2-Inch Petrol Pump | 6m Suction Hose | 25m Delivery Hose | Quick-Connect Camlocks | Engine Oil Included

What’s Included in the Bison WP20 Pump Kit?
| Component | Supplied arrangement |
|---|---|
| Bison WP20 petrol water pump | 2-inch / 50mm inlet and outlet, recoil-start engine and protective carry frame |
| 6m green MDS suction hose | 2-inch hose, assembled with a female Type C Camlock connection and suction strainer |
| 25m heavy-duty blue layflat delivery hose | 2-inch hose, assembled with a female Type C Camlock at one end and a male Type E Camlock at the other |
| Two aluminium Type A Camlock adaptors | Pump-side connections for the supplied hose assemblies |
| 1 litre of engine oil | Supplied separately for engine preparation and oil-level maintenance |
The included oil bottle is not an instruction to pour a full litre into the engine. Fill only to the level specified in the engine instructions.
You will also need petrol, clean water for priming and a suitable outdoor operating location. The kit still requires connection, pre-start checks and correct priming before use.
Why Choose the Complete Bundle?
- Hoses already assembled: The suction and delivery hoses arrive with their connection fittings attached, avoiding separate hose-assembly work.
- Quick connection between jobs: Once the pump-side adaptors are fitted, the Camlock couplings allow the hoses to be connected and disconnected without repeatedly unscrewing the pump connections.
- Extendable discharge arrangement: The delivery hose has compatible male and female Camlock ends, allowing another suitable hose assembly to be connected.
- One package to prepare: The pump, hoses, strainer, connection adaptors and engine oil are supplied together rather than sourced individually.
Technical Specifications
| Specification | Bison WP20 |
|---|---|
| Pump type | Surface-mounted, petrol engine-driven water pump |
| Operation | Manual |
| Inlet connection size | 2 inches / 50mm |
| Outlet connection size | 2 inches / 50mm |
| Published maximum flow | 420 litres/minute / 25.2m³/hour |
| Maximum total head | 28 metres |
| Published maximum suction lift | 7 metres |
| Engine displacement | 196cc |
| Engine type | Air-cooled, four-stroke petrol |
| Starting method | Recoil pull start |
| Fuel | Unleaded petrol |
| Fuel tank capacity | 3.6 litres |
| Engine protection | Low-oil shutdown |
| Supplied suction hose | 6 metres |
| Supplied delivery hose | 25 metres |
| Optional delivery extension | Additional 25m layflat hose assembly |
| Intended water | Clean or lightly dirty water without heavy contamination |
| Operating location | Outdoors only |
These are pump specifications, not guaranteed delivery figures through the supplied hoses. The actual pumping duty depends on the installation.
Construction Site Drainage, Flood Response and Water Transfer
Use the WP20 bundle for moving accumulated rainwater, transferring water between tanks and supporting irrigation where the water is suitable for a clean-water pump.
For construction and groundworks, assess the water before pumping. Clear or lightly dirty water is a different duty from an excavation containing concentrated sand, clay, rubble or thick mud.
The WP20 is not a trash pump, sewage pump or slurry pump. Its intake strainer helps keep larger debris out, but does not make heavily contaminated water suitable.
The same distinction applies to flood response: check for sewage, fuel, chemicals and substantial sediment before selecting the pump.
Understanding Flow, Head and Suction Lift
The WP20’s 420 litres per minute maximum flow and 28-metre maximum total head are separate limits. It does not deliver the maximum flow at the maximum head.
The pumping duty includes the lift from the source water surface to the discharge point and resistance through both hoses, connections and fittings. Longer runs, smaller hose diameters and additional restrictions reduce the available flow.
The 7-metre suction-lift figure describes the pump’s maximum published vertical lift from the water surface to the pump inlet. It is not a hose-length allowance or a guarantee of performance in every installation.
The bundle includes a 6-metre suction hose. Its usable vertical reach is less than its full length once the horizontal route and submerged intake are allowed for. Keep the pump as close to the source water level as safely practical.
Optional Additional 25-Metre Delivery Hose
An additional 25-metre layflat hose assembly with Camlock connections can be selected when ordering.
Connected to the standard hose, this provides 50 metres of delivery hose in total, giving more flexibility when routing water away from the pumping area.
Additional hose length does not increase the pump’s pressure or guarantee the same flow over a longer distance. Have the route checked where the discharge is uphill, lengthy or particularly restrictive.
Setting Up the Kit
Position the pump on firm, level ground outdoors, with the engine exhaust directed away from people and building openings.
Fit the pump-side adaptors, connect the assembled hoses and check that the couplings and seals are secure. Keep the suction strainer submerged and clear of loose sediment, and route the delivery hose without sharp bends or kinks.
Check the engine-oil level, add the specified fuel and fill the pump casing completely with clean water before starting. Follow the supplied instructions for the engine controls and starting procedure.
Monitor the water supply and discharge while operating. Stop the engine if the intake draws air, delivery stops or the pump loses prime.
Important Notes
Never operate the petrol engine indoors or in an enclosed space. Exhaust contains carbon monoxide, which can cause fatal poisoning. Opening doors or windows does not make indoor operation safe.
The pump must remain outside the water; only the suction hose and strainer are placed in the source.
Do not run the pump dry. Low-oil shutdown protects the engine’s lubrication system—it does not detect an empty tank or a loss of pumped water.
Stop the engine and allow it to cool before refuelling or carrying out maintenance. Follow the supplied instructions for servicing and storage.
Why Buy from Henry Pumps?
Choose a pump bundle with practical advice from an independent pump specialist.
Henry Pumps can help check the water condition, suction arrangement, discharge distance and required flow before you buy. Our team can also advise on additional hose assemblies, connection fittings and replacement parts.
Need Help or Advice?
Tell us what you are pumping, how far below the pump the water sits and where it needs to discharge.
Call 0333 050 3748 or email sales@henrypumps.co.uk for help selecting your site pump kit and accessories.
Customer reviews
-
Brand:Bison
-
Condition:New
-
Product Code:WP20PumpKit
-
Weight:25kg
Suitable for
- Construction site dewatering
- Outdoor rainwater and floodwater removal
- Garden and agricultural irrigation
- Clean-water tank and IBC transfer
Not suitable for
- Indoor or enclosed-space operation
- Sewage, sludge and fibrous wastewater
- Heavy sand, grit and debris-laden water
- Fuel, solvent and chemical transfer
Frequently Asked Questions
The bundle adds assembled suction and delivery hoses, Camlock connections, a suction strainer and engine oil to the WP20 pump.
It is intended for customers who need a pumping package rather than a pump to connect to existing equipment. The accessories make installation more convenient; they do not increase the pump’s hydraulic performance.
The hoses are supplied assembled, but the equipment still needs preparing before use.
Connect the hoses, check the engine oil, add petrol and prime the pump casing with clean water. Complete the checks in the supplied instructions before starting.
Do not assume the engine has already been filled with oil, or that the full one-litre bottle is the required fill quantity.
The female hose coupling fits over the matching male adaptor. Closing its two lever arms secures the connection against the internal seal.
This allows quick hose connection and removal once the threaded pump-side adaptors are installed.
Keep the sealing faces clean and check that the seals and levers are in good condition. Stop the pump and release pressure before disconnecting a hose.
Yes. The supplied delivery hose has a female Camlock at one end and a male Camlock at the other, allowing another compatible assembly to be joined.
The optional additional 25-metre hose brings the total delivery-hose length to 50 metres.
Check the discharge route before adding further lengths, because friction losses increase with hose length and reduce the available flow.
Potentially, provided the water is suitable and the suction arrangement is within the pump’s capability—but the petrol engine must remain outdoors.
Never run it inside the basement, garage or another enclosed space. Keep it well away from doors, windows and ventilation openings so exhaust cannot enter the building.
The suction hose must reach the water without exceeding the practical lift or available hose length.
Do not rely on it to do so.
The listed automatic protection is low-engine-oil shutdown, not water-level sensing. It does not establish that the pump will stop when the source becomes empty.
Monitor the water level and stop the engine before the intake draws air or the pump runs dry.
Follow the engine’s service schedule and check the oil level, air filter, suction strainer, hoses and coupling seals regularly.
Keep the intake clear and inspect the hose assemblies for damage or loose connections. Investigate reduced flow, loss of prime or unusual operating behaviour.
Stop the engine, allow it to cool and follow the manual’s isolation procedure before maintenance.
Buy with confidence
At Henry Pumps, we support residential, commercial, and industrial customers, from homeowners and landlords to contractors and facilities teams. Based in Derbyshire, we help solve flooding, drainage, and water management challenges across the UK. Every pump we supply is chosen for proven reliability and performance, backed by expert, straightforward advice you can trust. Whether you’re maintaining a property, managing a building, or dealing with an urgent issue, we’ll help you find the right solution.



