Koshin SEV-50D & SEV-80D Diesel Water Pumps – 2-Inch & 3-Inch
Diesel-Powered Water Transfer for Construction, Utilities and Agriculture
The Koshin SEV-50D and SEV-80D provide diesel-powered water transfer for construction sites, utilities, civil engineering and agricultural applications where mains electricity is unavailable or a diesel engine is preferred.
Both models combine a self-priming centrifugal pump with a Koshin KD300 four-stroke diesel engine. Recoil starting provides manual operation without a separate generator, while a protective tubular steel frame and anti-vibration mounts support use across temporary pumping installations.
Choose the 2-inch SEV-50D for duties requiring its higher delivery head, or the 3-inch SEV-80D where greater water-transfer capacity is the priority.
An aluminium pump housing, cast iron impeller and volute, and silicon carbide mechanical seal provide a robust pumping assembly for suitable clean-water service.
Koshin KD300 Diesel Engines | Recoil Start | 2-Inch or 3-Inch | Protective Steel Frames | Clean-Water Transfer

Why Choose a Koshin SEV Diesel Pump?
- Independent of mains electricity: Diesel power suits remote working areas and temporary installations without an electrical supply.
- Two distinct pumping duties: Choose higher head from the SEV-50D or greater maximum flow from the SEV-80D.
- Durable pumping components: Cast iron impellers and volutes are housed within aluminium casings.
- Connection accessories supplied: Hose couplings, bands and an intake strainer help prepare a suitable hose-connected installation.
Model Comparison and Technical Specifications
| Specification | Koshin SEV-50D | Koshin SEV-80D |
|---|---|---|
| Pump type | Self-priming centrifugal | Self-priming centrifugal |
| Inlet connection | 2-inch / 50mm BSP male | 3-inch BSP male |
| Outlet connection | 2-inch / 50mm BSP male | 3-inch BSP male |
| Maximum published flow | 630 litres/minute | 880 litres/minute |
| Maximum flow in m³/hour | 37.8m³/hour | 52.8m³/hour |
| Maximum total head | 32 metres | 25 metres |
| Maximum published suction lift | 8 metres | 8 metres |
| Engine | Koshin KD300 | Koshin KD300 |
| Engine type | Forced-air-cooled, four-stroke diesel | Forced-air-cooled, four-stroke diesel |
| Engine displacement | 296cc | 296cc |
| Starting method | Recoil pull start | Recoil pull start |
| Operating control | Manual | Manual |
| Fuel | Diesel | Diesel |
| Nominal fuel tank size | 3.5 litres | 3.5 litres |
| Specified fuel filling level | 3 litres | 3 litres |
| Published engine-oil capacity | 1.1 litres | 1.1 litres |
| Pump housing | Aluminium | Aluminium |
| Impeller and volute | Cast iron | Cast iron |
| Mechanical seal | Silicon carbide | Silicon carbide |
| Published dimensions, L × W × H | 600 × 520 × 550mm | 600 × 520 × 550mm |
| Published net weight | 46.1kg | 48.6kg |
| Intended liquid | Clear water | Clear water |
| Liquid temperature range | 5–45°C | 5–45°C |
| Operating location | Outdoors only | Outdoors only |
Maximum flow, maximum total head and maximum suction lift are separate limits. They are not available together as one operating duty.
SEV-50D or SEV-80D: Which Model Should You Choose?
SEV-50D — 2-Inch Pumping with Greater Delivery Head
The SEV-50D has a maximum published flow of 630 litres per minute and a maximum total head of 32 metres.
It is the model to consider where additional lift or pressure is more important than the greater maximum-flow capacity of the 3-inch version.
A 2-inch hose arrangement may also be more convenient where the larger equipment is unnecessary. Check the required flow at your operating head before selecting the pump.
SEV-80D — 3-Inch Higher-Volume Water Transfer
The SEV-80D increases maximum flow to 880 litres per minute, with 3-inch inlet and outlet connections.
Consider it for larger water volumes, tank emptying and transfer duties where the complete hose arrangement can accommodate the additional flow.
Its maximum head is 25 metres, compared with 32 metres for the SEV-50D. Moving to the larger pump does not automatically solve an uphill discharge or irrigation system requiring more pressure.

Clear & Slightly Dirty Water Pumping — Not Semi-Trash or Slurry Duty
The SEV diesel range is intended for clearer-water transfer, including suitable rainwater, tank water, construction site dewatering, and well water without heavy contamination.
For construction drainage or flood response, check the water condition before pumping. Water containing thick mud, concentrated silt, clay, sewage or substantial debris requires equipment selected for those materials.
Cast iron pumping components and silicon carbide sealing do not turn these models into trash pumps.
Keep the supplied strainer fitted and position it clear of accumulated sediment. Where debris or abrasive material is a significant part of the duty, ask Henry Pumps to assess a semi-trash, trash or specialist drainage pump instead.
Understanding Flow, Head and Suction Lift
The SEV-80D does not deliver 880 litres per minute at 25 metres head. Available flow falls as the head required by the installation increases.
The complete pumping duty includes the elevation difference between the source water surface and delivery point, resistance through both hoses and fittings, and any pressure required at the outlet.
For irrigation, sufficient pressure must remain at the sprinklers after the water has been lifted and moved through the supply hose.
The 8-metre suction-lift figure describes the maximum published vertical distance from the water surface to the pump inlet. It is not the suction-hose length or the depth of a well.
Keep the pump close to the source water level where safely practical, with a short, airtight suction arrangement. Allow for the water level falling during pumping.
Koshin KD300 Diesel Power
Both models use the 296cc Koshin KD300 engine, rather than a Honda petrol engine or a Yanmar diesel engine.
The recoil-start arrangement incorporates a decompression lever. Follow Koshin’s starting procedure rather than treating it as identical to starting a petrol pump.
Use the specified diesel fuel and maintain the engine oil separately. Keep dirt and water out of the fuel system, and check the oil before operation.
“Diesel pump” describes the engine’s fuel—not the liquid the pump is designed to transfer. These are water pumps, not diesel-fuel transfer pumps.
Fuel Tank and Oil Preparation
The published specification distinguishes between a 3.5-litre tank size and a 3-litre fuel filling level. Follow the marked filling limit and do not fill the tank to the brim.
The engine’s published oil capacity is 1.1 litres. Use the specified level-checking procedure with the engine stopped and level, rather than measuring the fill solely by bottle size.
A single one-litre oil bottle is less than the published capacity for an empty engine. Check what preparation is required on delivery and ensure enough suitable oil is available.
The KD300’s oil-bath air cleaner also requires inspection and servicing. Its oil requirement is separate from the engine’s main oil fill.
What’s Included?
The selected Koshin SEV diesel pump is supplied with its protective frame, one intake strainer, two hose-coupling sets, three hose bands and an engine tool set.
Full suction and delivery hose lengths are separate unless expressly added to your order. This is a pump-only listing, not an assembled hose bundle.
A one-litre bottle of engine oil can be selected as an optional addition. Select suitable hoses and connection equipment for the chosen pump size and intended duty.
Hose Selection and Priming
Use reinforced, suction-rated hose matching the pump’s inlet size. Ordinary layflat hose is unsuitable for suction because it can collapse under vacuum.
For delivery, use appropriately pressure-rated layflat or reinforced hose. Avoid unnecessary reductions, sharp bends and kinks.
Fill the pump casing completely with clean water before starting. Self-priming describes its ability to clear air from a correctly prepared suction arrangement; it does not eliminate the initial water fill.
Keep the strainer submerged and supported clear of loose sediment. Check coupling seals carefully, because suction-side air leaks can prevent priming even when the engine runs normally.
Important Notes
Operate outdoors only. Diesel exhaust contains carbon monoxide, which can cause fatal poisoning. Never run the engine in a building or enclosed or partly enclosed space, even with doors or windows open.
Keep the engine away from building openings. The pump unit must remain out of the water.
Do not run dry or leave the pump operating against a closed discharge. Monitor the source and receiving area, and stop the engine if delivery stops or the intake draws air.
Stop the engine and allow it to cool before refuelling or maintenance. Do not open pump plugs or disconnect hoses while the pumping section is hot or pressurised.
Use appropriate handling arrangements when moving the equipment. The protective frame does not make a pump of this weight suitable for one-person lifting.
Why Buy from Henry Pumps?
Get practical selection advice from an independent pump specialist.
Henry Pumps can help assess the water condition, required flow, suction lift and discharge route, then match the selected pump with suitable hoses and fittings.
Our team can also assist with maintenance guidance and replacement-part enquiries.
Need Help or Advice?
Tell us where the water is collecting, how far below the pump it sits and where it needs to discharge.
Call 0333 050 3748 or email sales@henrypumps.co.uk for help selecting your Koshin diesel pump and accessories.
Customer reviews
-
Condition:New
-
Product Code:SEV50D
-
Weight:46.1kg
Suitable for
- Clear-water construction and utilities dewatering
- Outdoor rainwater removal without heavy contamination
- Agricultural irrigation and freshwater transfer
- Filling or emptying tanks and reservoirs
Not suitable for
- Indoor or enclosed-space operation
- Sewage, sludge and fibrous wastewater
- Mud, concentrated silt and abrasive slurry
- Seawater, fuels and aggressive chemicals
Frequently Asked Questions
The SEV-50D has 2-inch connections, a maximum flow of 630 litres per minute and a maximum head of 32 metres.
The SEV-80D has 3-inch connections and increases maximum flow to 880 litres per minute, but its maximum head is 25 metres.
Choose the smaller model where its higher-head performance suits the duty, or the larger model where additional flow is required. Check the complete performance curve rather than selecting by connection size alone.
Both use a Koshin KD300, 296cc, four-stroke diesel engine.
The versions listed here use recoil pull starting, with a decompression lever forming part of the starting procedure. Electric start is not included in the listed configuration.
Follow the instructions supplied with the pump when starting and stopping the engine.
Yes. Fill the pump casing with clean water before starting the engine.
The suction line must also be airtight and the strainer properly submerged. Re-prime after draining the casing or losing prime.
If the engine runs without water delivery, stop it and investigate rather than allowing the pumping section to run dry.
The published maximum suction lift is 8 metres, measured vertically from the source water surface to the pump inlet.
It is not a guaranteed practical lift in every installation. Hose resistance, air leaks, atmospheric conditions and water temperature can affect performance.
Keep the pump as close to the water level as safely possible and allow for that level falling during pumping.
Follow Koshin’s service schedule for engine oil, air-cleaner and fuel-system maintenance. Inspect the intake strainer, suction connections, hoses and seals regularly.
Flush out deposits and drain the pumping section after use as instructed, particularly before storage where freezing could occur.
Stop and isolate the engine, allow hot components to cool and release system pressure before inspection or maintenance.
Buy with confidence
At Henry Pumps, we support residential, commercial, and industrial customers, from homeowners and landlords to contractors and facilities teams. Based in Derbyshire, we help solve flooding, drainage, and water management challenges across the UK. Every pump we supply is chosen for proven reliability and performance, backed by expert, straightforward advice you can trust. Whether you’re maintaining a property, managing a building, or dealing with an urgent issue, we’ll help you find the right solution.



