Arven Mizar VOX Light Sewage Vortex Pump – Manual or Automatic
The Arven Mizar VOX is a compact stainless steel submersible pump for dirty water containing soft suspended solids up to 20mm, including suitable final-effluent and very light sewage duties. It is a practical choice for drainage sumps, water collection chambers and water transfer around domestic, commercial and industrial premises.
Its top-discharge arrangement keeps the hose connection above the pump, while the water-cooled design allows operation under partial immersion within the stated temperature limit. The stainless steel casing and impeller provide durable construction for compatible drainage water, and the carrying handle makes the pump straightforward to position and retrieve.
Choose from 110V or 230V, with either manual operation or a pendant float switch for automatic starting and stopping. The automatic model suits recurring water collection where the sump provides enough room for the float to move freely.
For sewage applications, the Mizar VOX is intended for very light duties such as final effluent. Raw toilet waste, wipes and concentrated sewage sludge require a different pump selection.

Key features and benefits
-
20mm soft-solids passage: handles larger soft particles than the standard Mizar drainage models, making the VOX useful where collected water contains suspended debris.
-
304 stainless steel casing and impeller: provides corrosion-resistant construction for suitable clean and dirty water applications.
-
Water-cooled, top-discharge design: allows partial-immersion operation and keeps the discharge connection above the pump body.
-
Manual or automatic options: choose operator-controlled pumping or a fitted pendant float for repeated sump drainage.
-
110V and 230V versions: match the pump to the electrical supply available at the installation.
-
10m rubber power cable: gives useful positioning flexibility between the pump and a suitable electrical connection.
-
Carrying handle with rope attachment: helps with lowering and retrieving the pump without placing strain on its electrical cable.
Choosing manual or automatic operation
Manual Mizar VOX
The manual version has no fitted float switch. It runs when power is applied and requires an operator, or a separately specified control arrangement, to determine when it starts and stops.
Choose manual operation for supervised water transfer or an installation with suitable existing controls. As supplied, it does not provide automatic protection against a falling water level.
Automatic Mizar VOX
The automatic version has a pendant float attached by a flexible cable. Rising water lifts the float to start the pump; falling water lowers it to stop pumping.
The approximate published switching levels are:
-
Start: 290mm water level.
-
Stop: 125mm water level.
These are guide levels for the automatic version. Float positioning, cable arrangement and conditions within the sump can affect the actual switching points, so check operation by filling and draining the installed sump.
Allow sufficient space for the float to move without catching against the sump wall, discharge pipe or other equipment. The pump’s 154mm diameter describes the pump body; it does not establish the minimum width of an automatic installation.
Understanding its light sewage capability
The Mizar VOX is suitable for water carrying soft suspended solids within its 20mm passage limit. This can include final effluent from an appropriate wastewater treatment arrangement, provided the liquid remains within the pump’s operating limits.
The solids-passage figure describes the size of suitable particles that can pass through the pump. It does not establish suitability for wipes, cloth, long fibres, sanitary products or thick sludge. The VOX has no cutting or macerating mechanism.
For industrial or agricultural applications, describe the liquid as well as the particle size when selecting the pump. Chemically contaminated water, saline water, fuels and liquids containing substantial abrasive material require a separate compatibility assessment.
Partial immersion and low-water operation
Pumped water helps cool the motor, allowing the Mizar VOX to work while partially submerged. Observe the following maximum liquid temperatures:
-
35°C when fully submerged.
-
25°C when partially submerged.
Partial immersion still requires sufficient water for the pump to continue pumping properly. Stop manual operation before the intake begins drawing air, and keep the automatic model’s float free to operate.
Integral thermal protection helps protect the motor against overheating. It is not a water-level sensor and should not be used as the normal method of stopping the pump when water runs out.
The Mizar VOX is a sump and drainage pump. It is not designed to leave a floor almost dry, and its automatic stopping level should not be confused with a puddle pump’s residual-water specification.
Matching the pump to the discharge route
The Mizar VOX has a published maximum flow of 175 litres/minute, equivalent to 10.5m³/hour, and a maximum head of 7m.
These are separate performance limits. The pump cannot deliver its maximum flow at its maximum head. The flow available in an installation depends on the vertical lift from the water surface, hose diameter, hose length and resistance through bends, valves and other fittings.
The 32mm discharge size provides a useful starting point for hose selection. A narrow hose can substantially reduce flow and restrict the passage of debris. For a long discharge run, Henry Pumps can help assess whether a larger hose would improve the duty.
Install the pump on a stable base with the intake clear of settled sludge and debris. Arrange the discharge hose so that it does not obstruct the float or pull the pump out of position.

Technical specifications
Specifications shared by all four options
| Specification | Mizar VOX |
|---|---|
| Pump type | Submersible vortex pump for dirty water and very light sewage duties |
| Motor output, P2 | 0.45kW |
| Electrical supply | Single-phase AC, 50Hz |
| Available voltages | 110V or 230V, selected when ordering |
| Maximum flow | 175 litres/minute / 10.5m³/hour |
| Maximum head | 7m |
| Discharge size | 32mm / 1¼-inch nominal, top discharge |
| Maximum soft-solids passage | 20mm |
| Maximum submersion depth | 5m |
| Maximum liquid temperature, fully submerged | 35°C |
| Maximum liquid temperature, partially submerged | 25°C |
| Pump dimensions | 154mm diameter × 264mm high |
| Outer casing and impeller | 304 stainless steel |
| Shaft | 303 stainless steel |
| Shaft seal | Single mechanical seal with silicon carbide and NBR components |
| Motor protection rating | IP68 |
| Motor insulation | Class F |
| Thermal protection | Integral |
| Power cable | 10m rubber cable |
Model options and automatic switching levels
| Option | Water-level control | Approximate ON level | Approximate OFF level | Dry pump weight |
|---|---|---|---|---|
| Mizar VOX 110V manual | No fitted float switch | — | — | 5.9kg |
| Mizar VOX 230V manual | No fitted float switch | — | — | 5.9kg |
| Mizar VOX 110V automatic | Pendant float switch | 290mm | 125mm | 6.1kg |
| Mizar VOX 230V automatic | Pendant float switch | 290mm | 125mm | 6.1kg |
Performance: maximum flow and maximum head are separate limits. Select the pump using the flow required at the total head of the installation.
Motor power: 0.45kW is mechanical motor output, not electrical input or a running-cost figure.
Dimensions and weights: allow additional installation space for the float, hose and fittings. Published dry weights exclude the power cable, hoses and connections.
Submersion: the 5m immersion limit describes how deeply the pump may be submerged. It is separate from the 7m maximum pumping head.
What is supplied
-
Mizar VOX pump in the selected voltage and control configuration.
-
10m rubber power cable.
-
Fitted pendant float switch on automatic versions.
-
Integral carrying handle.
Useful installation accessories
-
Discharge hose or pipework: selected for the required length, flow and water type.
-
Matched connections and hose clips: to suit the pump’s outlet arrangement and the chosen discharge hose.
-
Suitable non-return valve: where the installation requires control of water draining back into the sump after stopping.
-
High-water alarm: useful in permanent installations where a rising water level needs separate attention.
-
Lifting rope: for lowering and retrieving the pump using its handle.
Valve selection should preserve suitable solids passage and account for the additional resistance it introduces. For automatic drainage, select the float-controlled pump unless the installation requires a separately designed control arrangement.
Help choosing your Mizar VOX
Henry Pumps is an independent pump specialist offering practical advice on pump selection, hoses, fittings and controls.
Tell us the water type, likely debris, vertical discharge height, hose length and available electrical supply. For an automatic installation, include the sump dimensions and the water levels at which pumping needs to start and stop.
Call 0333 050 3748 or email sales@henrypumps.co.uk for help choosing the appropriate Mizar VOX option and discharge equipment.

Customer reviews
-
Voltage:230v
-
Condition:New
-
Product Code:24101015
-
Weight:6kg
Suitable for
- Cellar and basement sumps
- Rainwater collection tanks
- Final-effluent chambers
- Commercial drainage sumps
Not suitable for
- Raw sewage and fibrous waste
- Heavy sludge and abrasive slurry
- Pond circulation
- Low-level puddle pumping
Frequently Asked Questions
It is suitable for very light sewage duties such as compatible final effluent. It should not be selected for raw toilet discharge, sewage containing wipes or sanitary products, or emptying concentrated sludge from a septic tank. Describe the actual liquid and waste content to Henry Pumps so the pump can be matched to the duty.
The VOX has a 20mm soft-solids passage and a stainless steel impeller. The standard UK Mizar 60 has a 10mm passage and a technopolymer impeller. Their performance also differs: the UK Mizar VOX is listed at 7m maximum head, compared with 10m for the standard Mizar 60. Choose according to both the water content and the required flow at the discharge height.
Choose manual operation for supervised pumping or an installation with suitable separate controls. Choose the automatic version when collected water needs to trigger the pump as the level rises. Its pendant float must have enough room to move freely. The manual pump has no automatic water-level switching as supplied.
The pump has a 32mm, or 1¼-inch nominal, discharge size. A suitably matched 32mm hose is a normal starting point, with the final selection depending on length, required flow and debris. A smaller hose can restrict performance and increase blockage risk. Longer runs may benefit from a larger bore, subject to checking the pump’s operating duty.
Yes, its water-cooled design permits partial-immersion operation while it is still pumping sufficient water. The maximum liquid temperature is 25°C under partial immersion, compared with 35°C when fully submerged. Partial immersion should not be treated as permission to leave the pump running completely dry, and thermal protection does not replace proper water-level control.
Isolate the electrical supply before inspection or cleaning. Remove debris from the intake, rinse away deposits after dirty-water use, and check the discharge route for restrictions. On automatic versions, check that the float moves freely and test a complete start-and-stop cycle using water. Inspect the cable and connections, and use the handle or a suitable lifting rope when retrieving the pump.
Buy with confidence
At Henry Pumps, we support residential, commercial, and industrial customers, from homeowners and landlords to contractors and facilities teams. Based in Derbyshire, we help solve flooding, drainage, and water management challenges across the UK. Every pump we supply is chosen for proven reliability and performance, backed by expert, straightforward advice you can trust. Whether you’re maintaining a property, managing a building, or dealing with an urgent issue, we’ll help you find the right solution.