JS RSD-400 Automatic Puddle Pump with Crab Sensor
Automatic clean-water drainage with approximately 1mm residue removal
The JS RSD-400 Automatic Puddle Pump with Crab Sensor combines a robust residue drainage pump with electronic water-level control. It is a practical choice for managing recurring clean-water accumulation in basements, cellars, plant rooms and other areas where shallow standing water needs to be removed.
The RSD-400 can reduce water to approximately 1mm on a smooth, level surface, while the supplied Crab sensor controls when the pump starts and stops. Adjustable delays allow the operating cycle to be matched to the installation.
With a maximum flow of 190 litres per minute, a maximum head of 11.5 metres, stainless steel and cast iron construction, and a cushioned rubber base, this automatic puddle pump suits contractors, facilities teams and property owners looking for a durable low-level drainage solution.

Key features and benefits
-
Automatic operation with the supplied Crab sensor: starts and stops the pump in response to water detection and the selected time delays.
-
Approximately 1mm residual drainage: helps remove the shallow water that remains on suitable flat surfaces.
-
Adjustable start and stop delays: use the supplied magnetic key to adapt the control settings to the application.
-
Stainless steel and cast iron construction: provides a robust pump assembly for property maintenance and clean-water drainage work.
-
Cushioned rubber base: helps protect the surface beneath the pump during use.
-
Integral suction-side non-return valve: helps retain water within the pump and limit water returning through the inlet after stopping.
-
10m power cable and stepped hose adaptor: provides practical connection options for a suitable discharge hose.
How the Crab automatic sensor works
The Crab is a weighted electronic sensor that rests on a flat surface beside the pump. Its contacts detect water through electrical conductivity, allowing it to control shallow-water drainage without needing the movement of a conventional swinging float.
The factory settings are:
| Control function | Factory setting |
|---|---|
| Start delay | Pump starts 5 seconds after the sensor detects water |
| Stop delay | Pump stops 30 seconds after the sensor no longer detects water |
The supplied magnetic key allows the start and stop delays to be adjusted independently, up to 120 seconds, following the controller instructions.
The start delay provides time for water to accumulate before pumping begins. The stop delay allows pumping to continue briefly after the sensor contacts become uncovered.
These are time settings, so the final water level depends on sensor placement, pump position, incoming water and the discharge arrangement. Test the complete operating cycle during setup and select delays that allow effective drainage without unnecessary running after water flow has stopped.
Priming and shallow-water starting
Before first use, the RSD-400 needs to be primed in accordance with the supplied instructions. Allow at least 5mm of water when establishing pumping.
The approximately 1mm figure describes the residual level the pump can achieve once water is flowing. Starting the pump requires a suitable prime and enough water at the inlet.
Position the pump upright on a firm, level surface, with the Crab where it can detect the water you want to remove. Keep the inlet clear and check that the discharge hose is securely connected and free from kinks.
Once everything is positioned, run a complete test to confirm that the pump starts, establishes flow and stops correctly. The automatic sensor controls switching; the pump still needs suitable operating conditions.
Robust construction for repeated drainage work
The RSD-400 uses a stainless steel outer casing, motor casing and shaft, together with cast iron components in the motor lid and pump housing.
Twin mechanical seals operate within a lubricated chamber, while the cushioned rubber bottom plate helps reduce direct contact between the pump’s metal components and the supporting surface.
An integral non-return valve at the suction inlet helps limit water flowing back through the pump when it stops. This is particularly useful during shallow-water drainage, where returning water could otherwise collect around the inlet again.
For effective operation, keep the valve, inlet and sensor contacts clean and include them in routine checks.
Technical specifications
| Specification | Details |
|---|---|
| Pump model | JS RSD-400 |
| Pump type | Submersible residue / puddle pump |
| Operation | Automatic through the supplied Crab electronic sensor |
| Voltage options | 110V or 230V, single-phase, 50Hz |
| Motor output | 0.4kW |
| Maximum flow | 190 litres per minute |
| Maximum head | 11.5m |
| Residual drainage level | Approximately 1mm on a suitable smooth, level surface |
| Starting water requirement | Allow at least 5mm when establishing pumping; initial priming required |
| Intended liquid | Clean water |
| Native discharge connection | 1¼-inch female BSP |
| Supplied stepped hose-tail adaptor | 25mm / 19mm / 15mm |
| Non-return valve | Integral valve at the suction inlet |
| Pump power cable | 10m |
| Crab sensor lead | 30cm |
| Factory start delay | 5 seconds after water detection |
| Factory stop delay | 30 seconds after water is no longer detected |
| Delay adjustment | Start and stop independently adjustable up to 120 seconds |
| Adjustment method | Supplied magnetic key |
| Pump-body dimensions | Approximately 370mm high × 167mm wide × 167mm long |
Maximum flow and maximum head are separate performance limits. The pump will deliver less water as the discharge height and resistance increase. Allow additional installation space for the Crab sensor, cable and hose connection.
What is included?
-
JS RSD-400 puddle pump in the selected voltage.
-
Crab automatic water-level sensor with 30cm lead.
-
Magnetic key for adjusting the sensor delays.
-
10m pump power cable.
-
Stepped hose-tail adaptor for 25mm, 19mm or 15mm hose.
-
Integral suction-side non-return valve and cushioned rubber base.
Discharge hose and hose clips are available separately.
Choosing a suitable discharge hose
The pump has a 1¼-inch female BSP outlet, while the supplied stepped adaptor accepts 25mm, 19mm and 15mm hose.
A suitable 25mm hose is a practical starting point when using the supplied adaptor. Smaller hose increases resistance and can substantially reduce the amount of water delivered, particularly over longer distances.
For longer hose runs or greater discharge heights, ask Henry Pumps to check the hose diameter and fittings against the required duty. A larger hose connection can be considered where appropriate, using additional fittings matched to the pump outlet.
Keep the discharge route as short and direct as practical, avoid tight bends, and position the outlet so discharged water cannot return to the area being drained.
Help choosing your automatic puddle pump
Henry Pumps is an independent UK pump specialist offering practical advice on pump selection, controls, discharge hoses and fittings.
Tell us where the water collects, how high it needs to be lifted and how far it needs to travel. We can help you assess whether the RSD-400 with Crab sensor is suitable and choose the accessories needed for your application.
Call 0333 050 3748 or email sales@henrypumps.co.uk.
Customer reviews
Cellar pump
So easy to use as the chap on the phone said. Just plug and pump. Saved my cellar from flooding.
Erica Huwkins | Chesterfield | September 2022
-
Brand:JS
-
Condition:New
-
Product Code:012-400A
-
Weight:15kg
Suitable for
- Basements and cellars
- Flat roofs and terraces
- Plant rooms and building maintenance
- Construction finishing and refurbishment
Not suitable for
- Raw sewage or fibrous waste
- Heavy mud or abrasive water
- Fuel, oils, solvents, seawater
- Chemical
Frequently Asked Questions
This version is supplied with a Crab electronic water-level sensor. When its contacts detect water, it starts the pump after the selected delay. When the contacts no longer detect water, it stops the pump after the selected run-on period.
This allows the pump to respond to recurring water accumulation once it has been correctly positioned, primed and tested.
The RSD-400 can drain down to approximately 1mm on a suitable smooth, level surface. The actual finish during automatic operation depends on the Crab’s position and delay settings, the pump’s placement and the rate at which water continues to arrive.
Uneven floors, surface channels and depressions can leave local puddles. Set up and test the complete arrangement to establish the result in your application.
Yes. The supplied magnetic key allows the start and stop delays to be adjusted independently, up to 120 seconds.
The factory settings are a five-second delay before starting and a 30-second delay before stopping. Follow the supplied controller instructions and check the result through a complete operating cycle. Extending the stop delay unnecessarily can leave the pump running after useful water flow has ended.
Yes. Prime the pump before initial use in accordance with its instructions, and allow at least 5mm of water when establishing pumping.
Priming prepares the pump’s internal water passages so it can establish flow in shallow water. Recheck the prime after storage or whenever the pump has drained internally. The automatic sensor does not fill or prime the pump.
Yes, where the water is clean and the pump can be safely positioned on a suitable surface.
Check access, the roof’s ability to accommodate the equipment and the discharge route before use. Remove leaves and loose debris, protect the roof covering as appropriate, and place the sensor where the water collects. The pump provides water removal; recurring pooling may also require attention to the roof drainage.
Yes. The RSD-400 incorporates a non-return valve at the suction inlet. It helps limit water returning through the pump and helps retain water internally between pumping cycles.
Keep the valve clean so it can close correctly. Any additional valve required in a fixed discharge installation should be selected for that installation.
Buy with confidence
At Henry Pumps, we support residential, commercial, and industrial customers, from homeowners and landlords to contractors and facilities teams. Based in Derbyshire, we help solve flooding, drainage, and water management challenges across the UK. Every pump we supply is chosen for proven reliability and performance, backed by expert, straightforward advice you can trust. Whether you’re maintaining a property, managing a building, or dealing with an urgent issue, we’ll help you find the right solution.