Tsurumi LSC1.4S Puddle Pump with Automatic Sensor
The Tsurumi LSC1.4S puddle pump with Sensor combines professional residue drainage with automatic electronic water-level control. It is designed for recurring water ingress, site drainage and flood clean-up applications where the pump needs to respond as water rises.
The fitted sensor uses two stainless steel probes to detect water. Once the water falls below the probes, the pump continues running for approximately one minute, allowing further drainage below the sensor level. Depending on the installation, the remaining water can be reduced to approximately 1mm.
Available in 110V and 230V, with a choice of 1 inch or 2 inch discharge connections, this version offers a maximum flow of 170 litres per minute and a maximum head of 11 metres.
The automatic starting level is determined by the fitted probe arrangement. The 1mm figure describes the pump’s finishing capability, rather than the depth at which it automatically starts.
Why Choose the LSC1.4S with Sensor?
-
Automatic response to rising water: the electronic sensor starts the pump when water reaches both probes.
-
Timed drainage below the probes: an approximately one-minute run-on period helps remove water below the activation level.
-
Residue removal down to approximately 1mm: useful for reducing the water left on suitable flat surfaces.
-
Compact electronic level control: avoids the clearance needed for a conventional swinging float.
-
Durable construction for site use: a steel outer casing, cast aluminium stand and wear-resistant hydraulic components suit demanding drainage work.
-
Flexible discharge arrangement: position the outlet vertically or horizontally to help route the hose without a sharp bend.

How the Automatic Sensor Works
The Sensor contains two stainless steel probes housed in moulded rubber.
Its operating sequence is straightforward:
-
Water rises to both probes: the sensor starts the pump.
-
Water drops below the probes: the pump continues for approximately one minute.
-
Water reaches the probes again during this period: pumping continues, with the timed cycle responding to the renewed water contact.
This allows the pump to drain below the point at which it started. The final depth depends on the area being drained, the incoming water, the discharge arrangement and how much water can be removed during the timed period.
On a suitable surface and under suitable conditions, the remaining water can be as low as approximately 1mm. This is not a separate fixed switching point measured by a probe at floor level.
Choosing the right starting level
The starting depth depends on the position and length of the fitted probes. Sensor extension kits are available as optional additions to alter the probe reach.
If you need pumping to begin before water reaches a particular height, check the required starting level with Henry Pumps before ordering. This is especially relevant for basements, shallow collection areas and locations where only a small amount of standing water is acceptable.
The sensor is supplied with probe extensions to enable pumping down to 85mm, or further, depending on the sump size/area being drained. The extensions are an optional extra for the standard Sensor.
Built for Professional Drainage Work
The LSC1.4S combines a pressed steel outer casing, cast aluminium stand and stainless steel shaft with rubber and urethane hydraulic components.
Its wear-resistant design suits drainage water containing sand and silt in suspension. The pump has a 6mm particle passage, although it should not be used for thick sludge, coarse debris or heavily loaded slurry.
A double mechanical seal operates in an oil chamber, with Tsurumi’s Oil Lifter helping maintain seal lubrication. An integral swing check valve helps reduce backflow from the discharge hose and retain priming water between operating cycles.
Available Versions
Choose the voltage to match your power supply and the discharge connection to suit the hose arrangement.
| Version | Outlet connection | Assembly dimensions: W × L × H |
|---|---|---|
| 110V with Sensor | 1 inch / 25mm BSP male | 227 × 196 × 316mm |
| 230V with Sensor | 1 inch / 25mm BSP male | 227 × 196 × 385mm |
| 110V with Sensor | 2 inch / 50mm BSP male | 227 × 196 × 316mm |
| 230V with Sensor | 2 inch / 50mm BSP male | 227 × 196 × 385mm |
Allow additional space for the discharge fitting, hose bend, probe arrangement and access for cleaning.
The outlet sizes are alternative configurations. Select the connection required for your installation when ordering.
Technical Specifications
| Specification | LSC1.4S with Sensor |
|---|---|
| Pump type | Submersible residue drainage pump |
| Control | Automatic electronic Sensor with two stainless steel probes |
| Power supply options | 110V or 230V, single phase |
| Motor output | 0.48kW / 480W |
| Maximum flow | 170 litres/minute |
| Maximum flow per hour | 10,200 litres/hour |
| Maximum head | 11 metres |
| Outlet options | 25mm / 1 inch or 50mm / 2 inch |
| Maximum particle passage | 6mm |
| Lowest residual water level | Approximately 1mm under suitable conditions |
| Automatic starting level | Determined by the fitted probe configuration |
| Run-on period | Approximately one minute after water drops below the probes |
| Water temperature range | 0–40°C |
| Power cable | 10 metres of heavy-duty rubber cable |
| Integral check valve | Fitted |
| Motor protection | Integral thermal protection |
| Dry weight | Approximately 12.7kg |
Maximum flow and maximum head are separate performance limits. Actual delivery depends on the lifting height and resistance through the hose and fittings.
Selecting the Discharge Hose
Choose a hose that matches the selected outlet and suits the discharge route.
A 1 inch hose can be convenient for a compact temporary drainage arrangement. A 2 inch hose provides a larger bore and can help reduce friction losses, particularly on longer runs.
Both versions have the same published maximum pump performance. The larger outlet does not double the pump’s flow.
Keep the hose route as direct as possible and avoid kinks, crushed sections and unnecessary restrictions. Henry Pumps can help you assess the hose length, discharge height and connections before ordering.
What Is Supplied?
This product includes:
-
The Tsurumi LSC1.4S pump in the selected voltage and outlet configuration.
-
The fitted electronic Sensor for automatic water-level control.
-
A 10 metre rubber power cable.
Discharge hose and any additional sensor extension kit should be selected to suit the installation.
If a particular starting depth is essential, ask Henry Pumps to check the sensor and extension arrangement before you choose the package.
Practical Pump-Selection Advice
Henry Pumps is an independent pump specialist offering advice on pumps, hoses, fittings and controls.
Tell us how quickly water enters the area, the depth at which pumping must begin, the available power supply and the discharge route. We can help you assess whether this Sensor version suits the job.
Call 0333 050 3748 or email sales@henrypumps.co.uk.
Full technical data sheet can be viewed by clicking here.
| Model | Voltage | Manual / Auto | Outlet (mm) | kW | Flow (l/min) | Head (metres) | WxLxH (mm) | On Level (mm) | Off Level (mm) | Dry weight (kg) | Packing weight |
| LSC1.4S Sensor | 110V | Automatic | 25 | 0.48 | 170 | 11 | 227x196x316 | 258 | 85 | 12.7 | 14.45 |
| LSC1.4S Sensor | 230V | Automatic | 25 | 0.48 | 170 | 11 | 227x196x316 | 258 | 85 | 12.7 | 14.45 |
| LSC1.4S (2") Sensor | 110V | Automatic | 50 | 0.48 | 170 | 11 | 227x196x316 | 258 | 85 | 12.7 | 14.45 |
| LSC1.4S (2") Sensor | 230V | Automatic | 50 | 0.48 | 170 | 11 | 227x196x316 | 258 | 85 | 12.7 | 14.45 |
Customer reviews
-
Voltage:230v
-
Brand:Tsurumi
-
Condition:New
-
Product Code:10101144
-
Weight:13kg
Suitable for
- Dirty Water, Standing Water
- Construction, Utilities, Hire Fleet
- Rainwater, Flooding, Groundwater
- Temperature: 0 - 40°C
Not suitable for
- Chemicals, Detergents, Fuels
- Sewage, Foul Water, Large Solids
- Salt & Sea Water
- Spa & Hot Tubs
Frequently Asked Questions
No. The 1mm figure is the potential finishing level once the pump is operating.
Automatic starting requires water to reach the fitted probes. Their position and extension arrangement determine the activation depth. If you need automatic response to a very shallow film of water, discuss that requirement with Henry Pumps before choosing this version.
No. The sensor uses a timed run-on period, rather than a separate probe measuring a fixed 1mm stopping level.
The pump may reduce the remaining water to approximately 1mm, but the result depends on the area being drained, incoming water, the surface and the discharge performance. A large area may retain more water when the timed period ends.
The extensions lengthen the sensing probes so that they can reach lower water levels.
The product options include 70mm and 170mm sensor extension kits. These extend the probes; they do not extend the power cable. Check the required arrangement with Henry Pumps if the pump must start at a particular depth.
Yes. The sensor controls operation, but the pump must still be primed.
For low-water starting, approximately 2.5 litres of clean water is added through the discharge hose coupling, following the operating instructions. Check correct pumping during initial setup.
Yes, provided the installation suits the pump’s operating levels and performance.
Check that its actual pumping rate exceeds the incoming flow and that the probe starting level is acceptable for the space. Test the completed installation, keep the probes and inlet clean, and inspect it regularly.
Automatic operation depends on an available electrical supply and a clear discharge route.
Isolate the power before cleaning or inspection. Remove deposits from the probes and inlet, check the hose for restrictions, and test the automatic cycle periodically.
Keep the check valve clean and follow the operating instructions for priming, seal inspection and maintenance.
Buy with confidence
At Henry Pumps, we support residential, commercial, and industrial customers, from homeowners and landlords to contractors and facilities teams. Based in Derbyshire, we help solve flooding, drainage, and water management challenges across the UK. Every pump we supply is chosen for proven reliability and performance, backed by expert, straightforward advice you can trust. Whether you’re maintaining a property, managing a building, or dealing with an urgent issue, we’ll help you find the right solution.