Villiers RT50VZB 2" Petrol Pump Flood Defence Kit Complete with Suction Hose, Layflat Hose & Fittings
Product code: RT50SiteKit
Petrol Water Pump, Suction Hose, Delivery Hose and Camlock Fittings
The Villiers RT50VZB Flood Defence Kit brings together a petrol-powered water pump, suction and delivery hoses, connection fittings and engine oil for outdoor flood response, construction drainage, irrigation and water transfer.
Built around the 2-inch Villiers RT50VZB centrifugal pump, the package provides a practical pumping solution for locations without mains electricity. Its four-stroke engine features recoil starting and low-oil protection, while a protective frame supports handling between jobs.
The pump has a published maximum flow of 600 litres per minute, making it an option for moving substantial volumes of suitable water from tanks, collection areas and flooded outdoor spaces.
Hoses and fittings are supplied loose for assembly before first use. This is not a pre-assembled hose kit.
2-Inch Petrol Pump | 6m Suction Hose | 20m Delivery Hose | Camlock Connections | Engine Oil Included

What’s Included?
| Component | Supplied with the kit |
|---|---|
| Villiers RT50VZB petrol pump | Four-stroke engine, recoil starter, low-oil alert and protective frame |
| Reinforced suction hose | 6 metres × 2 inches / 50mm |
| Layflat delivery hose | 20 metres × 2 inches / 50mm |
| Camlock fittings | Four 2-inch fittings: two pump-side connections and two hose-side connections |
| Hose clamps | Supplied for securing the hose fittings |
| Engine oil | One 1-litre bottle |
The hose connections must be fitted, secured and checked before operating the pump. Petrol and clean water for priming are also required.
Fill the engine only to its specified oil level. The one-litre bottle supplied is not a statement of the engine’s oil capacity.
Why Choose the Villiers RT50 Flood Kit?
- No mains electricity required: Petrol power makes the kit useful for remote sites and outdoor pumping during a power outage.
- Pump and hose equipment together: Avoid purchasing the pump, suction hose, delivery hose and connections individually.
- Quick hose removal after assembly: Camlock connections allow the hoses to be disconnected for transport and storage without repeatedly unscrewing the pump connections.
- Protective framed construction: The surrounding frame helps protect the pump and engine during handling, with anti-vibration mounts supporting the assembly.
Technical Specifications
| Specification | Villiers RT50VZB |
|---|---|
| Pump type | Surface-mounted centrifugal water pump |
| Engine | Villiers G160V four-stroke petrol |
| Starting method | Recoil pull start |
| Operation | Manual |
| Engine protection | Low-oil alert and shutdown |
| Inlet connection size | 2 inches / 50mm |
| Outlet connection size | 2 inches / 50mm |
| Published maximum flow | 600 litres/minute / 36m³/hour |
| Listed maximum total head | 28 metres |
| Published maximum suction lift | 7 metres |
| Supplied suction hose | 6 metres |
| Supplied delivery hose | 20 metres |
| Hose assembly | Fittings supplied loose |
| Operating location | Outdoors only |
Maximum flow and maximum head are separate figures. The pump does not deliver 600 litres per minute at 28 metres head, and the figures are not guaranteed delivery rates through the supplied hose arrangement.
Flood Response, Site Drainage and Agricultural Water Transfer
The RT50 kit is a practical choice for rainwater removal, clean-water site drainage, tank emptying and irrigation supplies, where the required duty falls within the pump’s capability.
Before pumping floodwater or excavation water, check what it contains. Water with limited contamination is a different application from thick mud, concentrated sand, sewage or debris-laden slurry.
The RT50VZB is not the Villiers RT80VWB trash pump. Do not assume that adding hoses gives the standard pump the solids-handling capability of a dedicated trash model.
Use an appropriate suction strainer and keep the intake away from unsuitable debris. Henry Pumps can help assess the water condition before recommending this kit.
Understanding Suction Lift and Delivery Distance
The 7-metre maximum suction lift describes the vertical distance from the source water surface to the pump inlet. It is not the total hose length or the depth of a well.
The kit contains a 6-metre suction hose, so its practical vertical reach is less than that once the horizontal route and submerged intake are allowed for. Position the pump as close to the water level as safely possible.
The delivery arrangement also affects performance. Water must overcome the discharge elevation and resistance through both hoses, couplings and fittings.
Twenty metres of delivery hose does not mean a 20-metre vertical lift at maximum flow. Have the complete route checked where water must travel uphill or through a long discharge line.
Assembly and First Use
Fit the pump-side Camlock connections and secure the hose-side fittings using the supplied clamps. Check the seals, threaded joints and hose connections carefully, particularly on the suction side, where an air leak can prevent successful priming.
Prepare and test the kit before storing it for emergency use. This provides an opportunity to check the assembly and become familiar with the engine controls before an urgent pumping task.
Before starting, check the engine oil, add the specified petrol and fill the pump casing completely with clean water. Keep the suction intake submerged and the delivery hose free from kinks.
Follow the instructions supplied with the pump for starting, stopping and routine servicing.
Oil Alert Does Not Detect an Empty Water Source
The oil-alert system protects the engine when its lubricating-oil level becomes too low.
It does not monitor the water entering the pump. An empty tank, exposed intake or leaking suction connection can cause the pump to lose water even when the engine has sufficient oil.
Monitor the water supply and stop the engine if the pump loses prime or delivery stops. Do not rely on oil alert to prevent dry running.
Important Notes
Never operate the petrol engine indoors or in an enclosed space. Exhaust contains carbon monoxide, which can cause fatal poisoning. Opening doors or windows does not make indoor operation safe.
Keep the engine outdoors, away from doors, windows and ventilation openings. The pump unit must not be submerged.
Do not run the pump dry. Self-priming capability still requires water in the pump casing before starting.
Stop the engine and allow it to cool before refuelling or maintenance. Do not use this water pump to transfer petrol, diesel, solvents or aggressive chemicals.
Why Buy from Henry Pumps?
Get practical advice from an independent pump specialist before choosing your flood-response equipment.
Henry Pumps can help check the water condition, suction lift, discharge route and required flow, as well as the fittings and accessories needed for your particular installation.
Need Help or Advice?
Tell us where the water is collecting, how far below the pump it sits and where it needs to discharge.
Call 0333 050 3748 or email sales@henrypumps.co.uk for help selecting your petrol pump kit and accessories.
Customer reviews
-
Brand:Villiers
-
Condition:New
-
Product Code:RT50SiteKit
-
Weight:26kg
Suitable for
- Outdoor rainwater and floodwater removal
- Construction site drainage
- Garden and agricultural irrigation
- Water transfer between tanks and reservoirs
Not suitable for
- Indoor or enclosed-space operation
- Sewage, sludge and fibrous wastewater
- Heavy sand, grit and abrasive slurry
- Fuel, solvent and aggressive-chemical transfer
Frequently Asked Questions
No. The hose fittings are supplied loose and need fitting before use.
Attach the connections securely, tighten the clamps and check the complete system before starting the pump. Camlocks make subsequent hose connection and removal convenient, but they do not remove the initial assembly requirement.
For emergency preparedness, assemble and test the equipment before it is needed.
The kit combines the RT50VZB with the suction and delivery equipment needed to build a hose-connected pumping arrangement.
This reduces the number of individual items to select and purchase. The additional equipment makes the pump more convenient to deploy; it does not increase its flow, pressure or solids-handling capability.
The female coupling fits over the matching male adaptor. Closing the two lever arms secures the connection against its internal seal.
Keep the sealing surfaces clean and inspect the seals and levers regularly. The hose fittings must first be properly secured to the hoses.
Stop the pump and release pressure before disconnecting a coupling.
Yes. Fill the pump casing with clean water before starting, following the supplied instructions.
Self-priming describes the pump’s ability to clear air from a correctly prepared suction arrangement. It does not mean that an empty pump can safely be started without water.
Re-prime after draining the pump or losing prime, and investigate suction leaks or blockages if it fails to deliver.
Potentially, provided the water is suitable and the suction hose can reach within the pump’s operating limits—but the engine must remain outdoors.
Never run it inside a basement, garage, shed or other enclosed space. Keep the engine away from building openings so exhaust cannot enter.
The water source, hose route and safe pump position must all be assessed before starting.
The kit includes one litre of engine oil.
Use the engine’s dipstick or specified level-checking method and follow its instructions. Do not pour in the full bottle simply because it is supplied.
Check the oil level before operation, even though the engine has an oil-alert system.
Follow the engine’s service schedule for oil, air-filter and spark-plug checks. Inspect the hoses, clamps, Camlock seals and intake strainer before use.
Drain and store the pumping equipment as instructed, protecting it from freezing and contamination.
Stop the engine, allow it to cool and follow the prescribed isolation procedure before cleaning or maintenance.
Buy with confidence
At Henry Pumps, we support residential, commercial, and industrial customers, from homeowners and landlords to contractors and facilities teams. Based in Derbyshire, we help solve flooding, drainage, and water management challenges across the UK. Every pump we supply is chosen for proven reliability and performance, backed by expert, straightforward advice you can trust. Whether you’re maintaining a property, managing a building, or dealing with an urgent issue, we’ll help you find the right solution.